Itho Daalderop connection table

Itho Daalderop

Curious whether a thermostat is suitable for your Itho Daalderop central heating boiler? View the connection table for all models of central heating boilers from Itho Daalderop here
Aansluittabel Savvycons

The control of the appliance is controlled by the thermostat, this can be done via on/off or modulating.

With an on/off control, the appliance is simply switched on or off and this control can also control a valve for district heating, for example. This arrangement is suitable for almost any device.

 

A modulating heating control allows the burner height of the appliance to burn at different positions. This ensures precise temperature controls and the burner activity of the boiler is precisely adapted to the heat demand. A modulating control thus achieves more efficiency from a low heating capacity.

 

In the table below you can look up your type of central heating boiler, in the columns next to it it is indicated which thermostat is suitable for your appliance and to which connection you should connect it.

Connection table

Type On off Round Opentherm
Aqua-Max And 1 in 2 And 1 in 2 And 1 in 2
Climax And 5 in 6 And 5 in 6 And 7 in 8
Kli-Max 2 And 3 in 4 And 3 in 4 And 1 in 2
HR Gas combi series And K1 (2x) (1) And K1 (2x) (1) And K3 (2x)
Multisolar series And K1 (2x) (1) And K1 (2x) (1) And K3 (2x)
CombiFort And K1 (2x) (1) And K1 (2x) (1) And K3 (2x)
CombiFort 2nd room thermostat And K2 (2x) (1) N.V.T. N.V.T.
CombiPact And K1 (2x) (1) And K1 (2x) (1) And K3 (2x)
CombiPact 2nd room thermostat And K2 (2x) (1) N.V.T. N.V.T.
Comfort Classic And K1 (2x) (1) And K1 (2x) (1) And K3 (2x)
Comfort Classic 2nd room thermostat And K2 (2x) (1) N.V.T. N.V.T.
CombinAir- zone 1 (LT) And K1 (2x) (1) And K1 (2x) (1) N.V.T.
CombinAir- zone 2 (HT) And K2 (2x) 1)     N.V.T.
HP Cube - zone 1 (LT) And divider 2 + 3 N.V.T. And Via Base Cube
HP Cube - see Base Cube 2nd thermostat N.V.T. N.V.T. N.V.T.
HP Cool Cube - zone 1 LT And divider 2 + 3 N.V.T. And Via Base Cube
HP Cool Cube - see Base Cube 2nd thermostat N.V.T. N.V.T. N.V.T.
Basic Cube (until September 2011) And Contact 1 + 2 N.V.T. And Contact 3 + 4
Basic Cube (Duo) And Contact 3a + 3b And Contact 3a + 3b And Contact 2a + 2b
Basic Cube (Duo) 2nd room thermostat And Contact 4a + 4b N.V.T. N.V.T.

(1) Room thermostat connection.

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Back to shop

Add Order Note Edit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

Coupon code will work on checkout page